Genie XC, HF and J boom lifts (S-60 XC, S-80 XC, S-85 XC, S-80 HF, S-85 HF, S-60 J, S-80 J)
Genie error code 89-15 — Fuel Level Sensor — Value to low
Message on the display: Fuel Level Sensor — Value to low
Code 89-15 occurs in machines: Genie S-80 XC, S-85 XC, S-80 HF, S-85 HF, S-60 XC, S-60 J, S-80 J.
message
The Genie display shows code 89-15 with the message “Fuel Level Sensor — Value to low”. It is an information message and does not need any reaction.
Effect on the machine: Information only.
Possible causes
- Fuel sensor shorted to GND.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
With a voltmeter, check voltage on C65FLI (BL/WH, TCON J7-11). The voltage should be between 1V and 5V. Check for shorts to ground.
Source: Genie Service and Repair Manuals (Part No. 1316494, 1315679, 1288652, 1280490, 1285305, 1285307), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 89-15 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 88-12Function Enable Valve — Circuit shorted to V+
- 88-15Function Enable Valve — Circuit shorted to GND
- 89-12Fuel Level Sensor — Value to high
- 92-11Turntable Rotate Flow Coil — Shorted to supply voltage
- 92-12Turntable Rotate Flow Valve — Circuit shorted to V+
- 92-15Turntable Rotate Flow Valve — Circuit shorted to GND