Genie error codes
Genie Z-40/23N, Z-40/23N RJ and Z-33/18: machine control
The code is made up of two numbers: the fault source and the fault type (e.g. 15-21), shown on the display of the machine's ground control box. Below are 119 codes with the original message from the manufacturer's manual, and for 118 of them the description, causes and solution in the manual's own words. They apply to these machines: Genie Z-40/23N, Z-40/23N RJ, Z-33/18 DC. Source: Genie Service and Repair Manuals (Part No. 119817, 1268528, 1268514), Fault Codes section.
- 11-12Battery Pwr — Out of range
- 11-15Battery Pwr — Value too low
- 12-15Pr5 Coil — Value too low
- 13-12Pr5 Contact — Value too high
- 13-15Pr5 Contact — Value too low
- 14-12Relief Valve — Value too high
- 14-16Relief Valve — Value at 0V
- 15-21Footswitch — Fault
- 15-22Footswitch — Fault Foot switch on within 200 milliseconds of power-up
- 15-24Footswitch — Time out
- 16-12Speed Dial — Value too high
- 17-12Lift Pump — Value too high
- 17-15Lift Pump — Value too low
- 17-21Lift Pump — Fault
- 17-22Lift Pump — Fault
- 18-21Tach Liftpmp — Fault
- 18-22Tach Liftpump — Fault
- 19-12Aux Pump — Value too high
- 19-15Aux Pump — Value too low
- 21-11Pri Ud Jystk — Shorted high (5V) Value too high Value too low Value at 0V
- 21-12Pri Ud Jystk — Shorted high (5V) Value too high Value too low Value at 0V
- 21-15Pri Ud Jystk — Shorted high (5V) Value too high Value too low Value at 0V
- 21-16Pri Ud Jystk — Shorted high (5V) Value too high Value too low Value at 0V
- 21-17Pri Ud Jystk — Not calibrated
- 22-12Pri Up Valve — Value too high
- 22-15Pri Up Valve — Value too low
- 23-12Pri Dn Valve — Value too high
- 23-15Pri Dn Valve — Value too low
- 25-11Pri Er Jystk — Shorted high (5V) Value too high Value too low Value at 0V
- 25-12Pri Er Jystk — Shorted high (5V) Value too high Value too low Value at 0V
Showing the first 30: type more digits of the code.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.