Genie Z-40/23N, Z-40/23N RJ and Z-33/18: machine control
Genie error code 67-19 — Dena Sw — Out of Range
Message on the display: Dena Sw — Out of Range
Code 67-19 occurs in machines: Genie Z-33/18 DC, Z-40/23N, Z-40/23N RJ.
blocking fault
PBOX Platform control box drive enable switch.
Description from the Genie service manual, in the original wording.
Effect on the machine: Drive Function disabled in drive disable zone.
Possible causes
The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Check for voltage output at drive enable toggle switch. (Blue) Check for voltage input at VCON at V1-4. Replace VCON.
Source: Genie Service and Repair Manuals (Part No. 119817, 1268528, 1268514), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 67-19 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system