Haulotte HA12 CJ and HA12 CJ+ (HA32 CJ)
Haulotte error code F01.03 — Problems in main contactor KMG or with the contactor for selection traction/pump KM1 (Open circuit, contact stuck or short-circuit)
Message on the display: Problems in main contactor KMG or with the contactor for selection traction/pump KM1 (Open circuit, contact stuck or short-circuit)
Code F01.03 occurs in machines: Haulotte HA12CJ, HA32CJ, HA12CJ+, HA32CJ+.
blocking fault
Problems in main contactor KMG or with the contactor for selection traction/pump KM1 (Open circuit, contact stuck or short-circuit)
Description from the Haulotte service manual, in the original wording.
Possible causes
- Possible faults on ZAPI (37, 74, 75, 76, 77, 242)
- Check the state of contactors and/or connections
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Possible faults on ZAPI (37, 74, 75, 76, 77, 242) • Check the state of contactors and/or connections
Source: Haulotte Maintenance Book HA12 CJ (4000786480), fault code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code F01.03 not go away?
RK Rental services Haulotte lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Haulotte service · Haulotte parts · All Haulotte codes of this system
Neighbouring Haulotte codes
- F01.01Problems in stator/rotor current, logic, hardware, current probes, or CAN bus network or problems linked to an over or low voltage
- F01.05Lack of power or problem in the outputs motors/pump
- F01.06Speed variator unit in thermal security
- F01.07Wrong sequence for starting or error on one speed variator unit input