Haulotte HA12 CJ and HA12 CJ+ (HA32 CJ)
Haulotte error code F01.07 — Wrong sequence for starting or error on one speed variator unit input
Message on the display: Wrong sequence for starting or error on one speed variator unit input
Code F01.07 occurs in machines: Haulotte HA12CJ, HA32CJ, HA12CJ+, HA32CJ+.
warning / function limited
Wrong sequence for starting or error on one speed variator unit input
Description from the Haulotte service manual, in the original wording.
Possible causes
- Restart the machine in good way (Battery cut-out, e- stop buttons then key selector for upper/lower control box)
- Check speed variator unit connection
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Restart the machine in good way (Battery cut-out, e- stop buttons then key selector for upper/lower control box) • Check speed variator unit connection
Source: Haulotte Maintenance Book HA12 CJ (4000786480), fault code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code F01.07 not go away?
RK Rental services Haulotte lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Haulotte service · Haulotte parts · All Haulotte codes of this system
Neighbouring Haulotte codes
- F01.03Problems in main contactor KMG or with the contactor for selection traction/pump KM1 (Open circuit, contact stuck or short-circuit)
- F01.05Lack of power or problem in the outputs motors/pump
- F01.06Speed variator unit in thermal security
- F01.08Problem on batteries or batteries too weak
- F02.01Output in open or short circuit : Pump power coil contactor KM2 is defective (or missing) or wire is cut
- F02.02Output in open or short circuit : Emergency pump power coil contactor KMS is defective (or missing) or wire is cut (Fault visible only if the Enable Switch SA10b is activated)