609 609 105609 609 104

Haulotte HA12 CJ and HA12 CJ+ (HA32 CJ)

Haulotte error code F01.07 — Wrong sequence for starting or error on one speed variator unit input

Message on the display: Wrong sequence for starting or error on one speed variator unit input

Code F01.07 occurs in machines: Haulotte HA12CJ, HA32CJ, HA12CJ+, HA32CJ+.

warning / function limited

Wrong sequence for starting or error on one speed variator unit input

Description from the Haulotte service manual, in the original wording.

Possible causes

  • Restart the machine in good way (Battery cut-out, e- stop buttons then key selector for upper/lower control box)
  • Check speed variator unit connection

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Restart the machine in good way (Battery cut-out, e- stop buttons then key selector for upper/lower control box) • Check speed variator unit connection

Source: Haulotte Maintenance Book HA12 CJ (4000786480), fault code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code F01.07 not go away?

RK Rental services Haulotte lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Haulotte service · Haulotte parts · All Haulotte codes of this system