JLG boom lifts (450AJ, 600AJ, 800AJ, 460SJ, 660SJ, 860SJ, 1250AJP, M450AJ, M600JP)
JLG error code 3213 — MAIN CONTACTOR DRIVER - PERMANENTLY ON
Message on the display: MAIN CONTACTOR DRIVER - PERMANENTLY ON
Code 3213 occurs in machines: JLG M600JP, E600JP.
blocking fault
Master Traction Module detects that the line contactor driver output failed short or contactor coil is disconnected/open circuit.
Description from the JLG service manual, in the original wording.
Possible causes
The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.
Checks from the manual
- Power cycle
What service does
A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.
Source: JLG Service and Maintenance Manuals: 600AJ (3121201), 800AJ (3120858), 460SJ, 860SJ, 1250AJP (3122581800), M450AJ (3121829), M600JP (3121711), Diagnostic Trouble Codes tables.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 3213 not go away?
RK Rental services JLG lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.