JLG boom lifts (450AJ, 600AJ, 800AJ, 460SJ, 660SJ, 860SJ, 1250AJP, M450AJ, M600JP)
JLG error code 6614 — CANBUS FAILURE - MAIN ANGLE SENSOR #1
Message on the display: CANBUS FAILURE - MAIN ANGLE SENSOR #1 · flash code 6/6
Code 6614 occurs in machines: JLG 1250AJP, 1100S, 1100SJP.
blocking fault
CANbus communications has been lost between the UGM and the main angle sensor #1. Machine is placed in retreival sequence for recovery. Fault cleared with power cycle
Description from the JLG service manual, in the original wording.
Possible causes
The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.
Checks from the manual
- Verify CANbus wiring per electrical schematic, verify CANbus resistance. Verify sensor wiring per electrical schematic.
What service does
A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.
Source: JLG Service and Maintenance Manuals: 600AJ (3121201), 800AJ (3120858), 460SJ, 860SJ, 1250AJP (3122581800), M450AJ (3121829), M600JP (3121711), Diagnostic Trouble Codes tables.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 6614 not go away?
RK Rental services JLG lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.