609 609 105609 609 104

JLG boom lifts (450AJ, 600AJ, 800AJ, 460SJ, 660SJ, 860SJ, 1250AJP, M450AJ, M600JP)

JLG error code 6655 — CANBUS FAILURE - REAR RIGHT MODUL

Message on the display: CANBUS FAILURE - REAR RIGHT MODUL

Code 6655 occurs in machines: JLG M600JP, E600JP.

blocking fault

After Startup complete, UGM or Power Modules not receive the designated CAN messages in 200ms (250ms for UGM)

Description from the JLG service manual, in the original wording.

Possible causes

The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.

Checks from the manual

  • UGM receives all traction modules CAN2 messages and shall command main contactor closed; once fault reset, motion permitted after controls are initialized. If CAN messages are lost more than 5 times, the fault shall be latched until Power Cycle.

What service does

A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.

Source: JLG Service and Maintenance Manuals: 600AJ (3121201), 800AJ (3120858), 460SJ, 860SJ, 1250AJP (3122581800), M450AJ (3121829), M600JP (3121711), Diagnostic Trouble Codes tables.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 6655 not go away?

RK Rental services JLG lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

JLG service · JLG parts · All JLG codes of this system