JLG boom lifts (450AJ, 600AJ, 800AJ, 460SJ, 660SJ, 860SJ, 1250AJP, M450AJ, M600JP)
JLG error code 84153 — BOOM LENGTH SENSOR 1 FAULTY - REPLACE/RECALIBRATE SENSOR
Message on the display: BOOM LENGTH SENSOR 1 FAULTY - REPLACE/RECALIBRATE SENSOR
Code 84153 occurs in machines: JLG 1250AJP.
blocking fault
There are three ways (a, b, c) that these faults can be set: (a) If the length sensor voltage changes more than 0.0168 volts within 40 milliseconds a counter for the respective length sensor shall be incremented to aid service in diagnosing bad sensor performance. The counter below shall be incremented anytime the description above is met. It is cleared/reset by a power cycle BmLenSnsr(1/2)Fault-Counter PowerCycle > _ 20 (b) The counter below shall be incremented every time BmLenSnsr(1/2)FaultCounter _ PowerCycle (described above) reached its threshold. This value is stored in EEPROM in order to track the history of the issue. (A successful Boom Sensor Calibration will reset this counter - t
Description from the JLG service manual, in the original wording.
Possible causes
The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.
Checks from the manual
- Check wiring and hardware Replace sensor and recalibrate.
What service does
A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.
Source: JLG Service and Maintenance Manuals: 600AJ (3121201), 800AJ (3120858), 460SJ, 860SJ, 1250AJP (3122581800), M450AJ (3121829), M600JP (3121711), Diagnostic Trouble Codes tables.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 84153 not go away?
RK Rental services JLG lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Neighbouring JLG codes
- 66111CANBUS FAILURE - CONNECTIVITY MODULE
- 84151TOWER LENGTH SENSOR 1 FAULTY - REPLACE/RECALIBRATE SENSOR
- 84152TOWER LENGTH SENSOR 2FAULTY - REPLACE/RECALIBRATE SENSOR
- 84154BOOM LENGTH SENSOR 2 FAULTY - REPLACE/RECALIBRATE SENSOR
- 84185TOWER ANGLE SENSOR #1 - COMMUNICATIONS FAULT
- 84186TOWER ANGLE SENSOR #2 - COMMUNICATIONS FAULT