JLG error code 2210 — TRIGGER CLOSED TOO LONG WHILE IN NEUTRAL

Message on the display: TRIGGER CLOSED TOO LONG WHILE IN NEUTRAL

Code 2210 occurs in machines: JLG ES series, 1932RS, 6RS, 3248RS, 10RS, 4045R, R4045.

warning / function limited

The trigger switch was closed for more than five seconds while the joystick was centered.

Description from the JLG service manual, in the original wording.

Possible causes

The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.

Checks from the manual

  • Check if the trigger switch is obstructed or jammed.
  • Check the trigger switch signal and wiring to the platform board. The trigger input (24V) is from platform board terminal J1-1, and its output (24V when closed) is to platform board terminal J1-8.
  • Replace platform board.

What service does

A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.

Source: JLG Service and Maintenance Manual, ES series (Diagnostic Trouble Codes section).

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.