| 001 | EVERYTHING OK | message |
| 002 | GROUND MODE OK | message |
| 003 | ALARM SOUNDING - TILTED & ABOVE ELEVATION | warning / function limited |
| 004 | DRIVING AT CUTBACK - ABOVE ELEVATION | warning / function limited |
| 005 | DRIVE & LIFT UP PREVENTED - TILTED & ELEVATED | blocking fault |
| 006 | LIFT UP PREVENTED - MAX HEIGHT ZONE A | blocking fault |
| 007 | DRIVING AT CUTBACK - POTHOLE STILL ENGAGED | warning / function limited |
| 008 | FUNCTIONS LOCKED OUT - SYSTEM POWERED DOWN | warning / function limited |
| 009 | DRIVE PREVENTED - ELEVATED ABOVE DRIVE CUTOUT HEIGHT | blocking fault |
| 211 | POWER CYCLE | message |
| 212 | KEYSWITCH FAULTY | blocking fault |
| 221 | FUNCTION PROBLEM - HORN PERMANENTLY SELECTED | warning / function limited |
| 222 | FUNCTION PROBLEM - INDOOR / OUTDOOR PERMANENTLY SELECTED | warning / function limited |
| 223 | FUNCTION PROBLEM - DRIVE & LIFT ACTIVE TOGETHER | blocking fault |
| 224 | FUNCTION PROBLEM - STEER LEFT PERMANENTLY SELECTED | warning / function limited |
| 225 | FUNCTION PROBLEM - STEER RIGHT PERMANENTLY SELECTED | warning / function limited |
| 226 | ACCELERATOR FAULTY - WIPER OUT OF RANGE | blocking fault |
| 227 | STEER SWITCHES FAULTY | warning / function limited |
| 228 | FUNCTION LOCKED OUT - ACCELERATOR NOT CENTERED | blocking fault |
| 229 | FUNCTION PROBLEM - TRIGGER PERMANENTLY CLOSED | warning / function limited |
| 231 | FUNCTION PROBLEM - LIFT PERMANENTLY SELECTED | warning / function limited |
| 232 | GROUND LIFT UP / DOWN ACTIVE TOGETHER | warning / function limited |
| 233 | FUNCTION PROBLEM - BRAKE RELEASE PERMANENTLY SELECTED | warning / function limited |
| 251 | ELEV ANGLE SENSOR FAULTY - VOLTAGE OUT OF RANGE | blocking fault |
| 252 | ELEV ANGLE SENSOR HAS NOT BEEN CALIBRATED | warning / function limited |
| 253 | DRIVE PREVENTED - CHARGER CONNECTED | blocking fault |
| 254 | DRIVE & LIFT UP PREVENTED - CHARGER CONNECTED | blocking fault |
| 255 | PLATFORM OVERLOADED | blocking fault |
| 256 | DRIVE PREVENTED - POTHOLE NOT ENGAGED | blocking fault |
| 257 | ELEV PROX PERMANENTLY CLOSED - CHECK PROX AND ANGLE ADJUSTMENT | warning / function limited |
| 258 | DRIVE & LIFT PREVENTED - BRAKES ELECTRICALLY RELEASED FOR TOWING | blocking fault |
| 259 | MODEL CHANGED - HYDRAULICS SUSPENDED - CYCLE EMS | blocking fault |
| 311 | OPEN CIRCUIT LINE CONTACTOR | blocking fault |
| 312 | CONTACTOR DRIVER PERMANENTLY OFF | blocking fault |
| 314 | AUXILIARY RELAY - OPEN CIRCUIT | blocking fault |
| 321 | LINE CONTACTOR MISWIRED ON OR WELDED | blocking fault |
| 322 | CONTACTOR DRIVER PERMANENTLY ON | blocking fault |
| 326 | AUXILIARY RELAY SHORT TO BATTERY | blocking fault |
| 331 | BRAKE SHORT TO BATTERY | blocking fault |
| 332 | BRAKE OPEN CIRCUIT | blocking fault |
| 333 | LIFT UP SHORT TO BATTERY | blocking fault |
| 334 | LIFT UP OPEN CIRCUIT | blocking fault |
| 335 | LIFT DN SHORT TO BATTERY | blocking fault |
| 336 | LIFT DN OPEN CIRCUIT | blocking fault |
| 337 | STEER LEFT SHORT TO BATTERY | blocking fault |
| 338 | STEER LEFT OPEN CIRCUIT | blocking fault |
| 339 | STEER RIGHT SHORT TO BATTERY | blocking fault |
| 421 | POWER MODULE TOO HOT - PLEASE WAIT | warning / function limited |
| 422 | DRIVING AT CUTBACK - POWER MODULE CURRENT LIMIT | warning / function limited |
| 423 | LIFT UP AT CUTBACK - POWER MODULE CURRENT LIMIT | warning / function limited |
| 441 | BATTERY VOLTAGE TOO LOW - SYSTEM SHUTDOWN | blocking fault |
| 442 | BATTERY VOLTAGE TOO HIGH - SYSTEM SHUTDOWN | blocking fault |
| 443 | LSS BATTERY VOLTAGE TOO HIGH | blocking fault |
| 444 | LSS BATTERY VOLTAGE TOO LOW | blocking fault |
| 446 | LOGIC SUPPLY VOLTAGE OUT OF RANGE | blocking fault |
| 661 | CANBUS FAILURE - POWER MODULE | blocking fault |
| 662 | CANBUS FAILURE - PLATFORM MODULE | blocking fault |
| 663 | CANBUS FAILURE - LOAD SENSING SYSTEM MODULE | blocking fault |
| 664 | CANBUS FAILURE - ACCESSORY MODULE | warning / function limited |
| 671 | ACCESSORY FAULT | warning / function limited |
| 771 | OPEN CIRCUIT DRIVE MOTOR WIRING | blocking fault |
| 772 | STALLED TRACTION MOTOR OR POWER WIRING ERROR | blocking fault |
| 773 | CAPACITOR BANK FAULT - CHECK POWER CIRCUITS | blocking fault |
| 774 | SHORT CIRCUIT FIELD WIRING | blocking fault |
| 775 | OPEN CIRCUIT FIELD WIRING | blocking fault |
| 776 | STALLED PUMP MOTOR OR POWER WIRING ERROR | blocking fault |
| 777 | OPEN CIRCUIT PUMP MOTOR WIRING | blocking fault |
| 778 | TRACTION T HIGH - CHECK POWER CIRCUITS | blocking fault |
| 779 | TRACTION T LOW - CHECK POWER CIRCUITS | blocking fault |
| 811 | TILT SENSOR NOT CALIBRATED | warning / function limited |
| 812 | NO DATA FROM TILT SENSOR - NOT CONNECTED OR FAULTY | blocking fault |
| 821 | LSS CELL #1 ERROR | warning / function limited |
| 822 | LSS CELL #2 ERROR | warning / function limited |
| 823 | LSS CELL #3 ERROR | warning / function limited |
| 824 | LSS CELL #4 ERROR | warning / function limited |
| 825 | LSS HAS NOT BEEN CALIBRATED | warning / function limited |
| 991 | LSS WATCHDOG RESET | warning / function limited |
| 992 | LSS EEPROM ERROR | warning / function limited |
| 993 | LSS INTERNAL ERROR - PIN EXCITATION | warning / function limited |
| 994 | LSS INTERNAL ERROR - DRDY MISSING FROM A/D | warning / function limited |
| 995 | POWER MODULE FAILURE - PERSONALITY RANGE ERROR | blocking fault |
| 996 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 997 | POWER MODULE FAILURE - CHECK POWER CIRCUITS OR MOSFET SHORT CIRCUIT | blocking fault |
| 998 | EEPROM FAILURE - CHECK ALL SETTINGS | blocking fault |
| 999 | FUNCTION LOCKED OUT - POWER MODULE SOFTWARE VERSION IMPROPER | blocking fault |
| 2210 | TRIGGER CLOSED TOO LONG WHILE IN NEUTRAL | warning / function limited |
| 2211 | FOOTSWITCH CLOSED TOO LONG WHILE IN NEUTRAL | warning / function limited |
| 2232 | FUNCTION PROBLEM - DRIVE & LIFT BOTH OPEN | blocking fault |
| 2510 | DRIVE PREVENTED - BRAKES NOT RELEASING | blocking fault |
| 2511 | ELEV ANGLE SENSOR FAULTY - NOT MOUNTED | blocking fault |
| 2512 | ELEV ANGLE SENSOR NOT DETECTING CHANGE | blocking fault |
| 3310 | STEER RIGHT OPEN CIRCUIT | blocking fault |
| 3311 | GROUND ALARM SHORT TO BATTERY | blocking fault |
| 3312 | LEFT BRAKE SHORT TO BATTERY | blocking fault |
| 3313 | RIGHT BRAKE SHORT TO BATTERY | blocking fault |
| 3314 | LEFT BRAKE OPEN CIRCUIT | blocking fault |
| 3315 | RIGHT BRAKE OPEN CIRCUIT | blocking fault |
| 4421 | LOGIC SUPPLY VOLTAGE OUT OF RANGE | blocking fault |
| 4422 | LOGIC SUPPLY VOLTAGE OUT OF RANGE | blocking fault |
| 6635 | CANBUS FAILURE - CHASSIS TILT SENSOR | blocking fault |
| 7710 | PUMP P HIGH - CHECK POWER CIRCUITS | blocking fault |
| 7711 | PUMP P LOW - CHECK POWER CIRCUITS | blocking fault |
| 7741 | ARMATURE BRAKING CURRENT TOO HIGH | blocking fault |
| 7742 | FIELD VOLTAGE IMPROPER | blocking fault |
| 9910 | FUNCTION LOCKED OUT - PLATFORM MODULE SOFTWARE VERSION IMPROPER | blocking fault |
| 9911 | FUNCTION LOCKED OUT - LSS MODULE SOFTWARE VERSION IMPROPER | blocking fault |
| 9912 | POWER MODULE FAILURE - SYSTEM MONITOR | blocking fault |
| 9917 | HIGH RESOLUTION ANALOG TO DIGITAL FAILURE - INTERRUPT LOST | blocking fault |
| 9924 | FUNCTIONS LOCKED OUT - MACHINE NOT CONFIGURED | blocking fault |
| 9950 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9951 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9952 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9953 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9954 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9955 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9956 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9957 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9958 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9960 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9962 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9963 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9964 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9969 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9970 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 9971 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 33297 | LEFT BRAKE - SHORT TO GROUND | blocking fault |
| 33298 | STEER LEFT VALVE - SHORT TO GROUND | blocking fault |
| 33299 | LINE CONTACTOR COIL - SHORT TO BATTERY | blocking fault |
| 33302 | NEGATIVE SUPPLY - SHORT TO BATTERY | blocking fault |
| 33303 | NEGATIVE SUPPLY - SHORT TO GROUND | blocking fault |
| 33304 | RIGHT BRAKE - SHORT TO GROUND | blocking fault |
| 33305 | STEER RIGHT VALVE - SHORT TO GROUND | blocking fault |
| 33383 | BEACON LIGHT- OPEN CIRCUIT | warning / function limited |
| 33384 | BEACON LIGHT - SHORT TO GROUND | warning / function limited |
| 33406 | LiFT UP VALVE - SHORT TO GROUND | blocking fault |
| 33407 | LIFT DN VALVE - SHORT TO GROUND | blocking fault |
| 33562 | BEACON LIGHT - SHORT TO BATTERY | warning / function limited |
| 99143 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 99144 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 99145 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 99146 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 99147 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 99148 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 99149 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 241 | AMBIENT TEMPERATURE SENSOR - OUT OF RANGE LOW | warning / function limited |
| 242 | AMBIENT TEMPERATURE SENSOR - OUT OF RANGE HIGH | warning / function limited |
| 324 | VALVE ENABLE DRIVER PERMANENTLY ON | blocking fault |
| 426 | MASTER MODULE TEMPERATURE - OUT OF RANGE | warning / function limited |
| 447 | VOLTAGE REFERENCE OUT OF RANGE | blocking fault |
| 448 | VOLTAGE REFERENCE OUT OF RANGE | blocking fault |
| 2520 | FUNCTIONS LOCKED OUT - CONSTANT DATA VERSION IMPROPER | blocking fault |
| 2568 | TEMPERATURE CUTOUT ACTIVE - AMBIENT TEMPERATURE TOO LOW | warning / function limited |
| 3213 | POWER MODULE MAIN CONTACTOR - SHORT TO GROUND OR OPEN CIRCUIT | blocking fault |
| 3349 | LINE CONTACTOR COIL - SHORT TO GROUND | blocking fault |
| 3368 | TWO SPEED VALVE - SHORT TO GROUND | warning / function limited |
| 3369 | TWO SPEED VALVE - OPEN CIRCUIT | warning / function limited |
| 3370 | TWO SPEED VALVE - SHORT TO BATTERY | warning / function limited |
| 3371 | GROUND ALARM- SHORT TO GROUND | warning / function limited |
| 3379 | HOUR METER- SHORT TO GROUND | warning / function limited |
| 3380 | HOUR METER- OPEN CIRCUIT | warning / function limited |
| 3381 | HOUR METER- SHORT TO BATTERY | warning / function limited |
| 4235 | POWER MODULE TOO HOT - REDUCED OPERATION | warning / function limited |
| 4236 | POWER MODULE TOO COLD - MODULE SHUTDOWN | blocking fault |
| 4424 | POWER MODULE VOLTAGE TOO LOW - MODULE SHUTDOWN | blocking fault |
| 4425 | POWER MODULE VOLTAGE TOO HIGH - MODULE SHUTDOWN | blocking fault |
| 4473 | POWER MODULE VOLTAGE TOO LOW - REDUCED OPERATION | warning / function limited |
| 4474 | POWER MODULE VOLTAGE TOO HIGH - REDUCED OPERATION | warning / function limited |
| 4475 | POWER MODULE - BDI FAULT | blocking fault |
| 4476 | BATTERY VOLTAGE TOO HIGH - UNPLUG CHARGER | blocking fault |
| 4477 | BATTERY VOLTAGE TOO HIGH - FORCING DISCHARGE | blocking fault |
| 4478 | GROUND MODULE - OVERCURRENT | blocking fault |
| 6643 | CANBUS FAILURE - LSS ANGLE SENSOR | blocking fault |
| 6649 | CANBUS FAILURE - TILT/TEMP SENSOR | blocking fault |
| 8212 | LSS PRESSURE SENSOR - DISAGREEMENT | blocking fault |
| 8213 | LSS ANGLE SENSOR - DIRECTION DISAGREEMENT | blocking fault |
| 8214 | LSS ANGLE SENSOR - OUT OF RANGE HIGH | blocking fault |
| 8215 | LSS ANGLE SENSOR - OUT OF RANGE LOW | blocking fault |
| 8216 | LSS ANGLE SENSOR HAS NOT BEEN CALIBRATED | blocking fault |
| 9949 | MACHINE CONFIGURATION OUT OF RANGE - CHECK ALL SETTINGS | blocking fault |
| 9959 | POWER MODULE FAILURE - INTERNAL ERROR | blocking fault |
| 23196 | PRESSURE SENSOR 1 OUT OF RANGE HIGH | blocking fault |
| 23197 | PRESSURE SENSOR 1 OUT OF RANGE LOW | blocking fault |
| 23198 | PRESSURE SENSOR 2 OUT OF RANGE HIGH | blocking fault |
| 23199 | PRESSURE SENSOR 2 OUT OF RANGE LOW | blocking fault |
| 23200 | LIFT UP SWITCH - INVALID SIGNAL | blocking fault |
| 23201 | LIFT DOWN SWITCH - INVALID SIGNAL | blocking fault |
| 23202 | POT HOLE PREVENTION SWITCH 1 - INVALID SIGNAL | blocking fault |
| 23203 | POT HOLE PREVENTION SWITCH 2 - INVALID SIGNAL | blocking fault |
| 23204 | CHARGE INTERLOCK - INVALID SIGNAL | blocking fault |
| 23205 | ELEVATION SENSORS - INVALID SIGNAL | blocking fault |
| 33208 | HORN - SHORT TO BATTERY | warning / function limited |
| 33209 | HORN SHORT TO GROUND | warning / function limited |
| 33317 | DRIVE FORWARD VALVE - OPEN CIRCUIT | blocking fault |
| 33318 | DRIVE FORWARD VALVE - SHORT TO BATTERY | blocking fault |
| 33319 | DRIVE FORWARD VALVE - SHORT TO GROUND | blocking fault |
| 33320 | DRIVE REVERSE VALVE - OPEN CIRCUIT | blocking fault |
| 33321 | DRIVE REVERSE VALVE - SHORT TO BATTERY | blocking fault |
| 33322 | DRIVE REVERSE VALVE - SHORT TO GROUND | blocking fault |
| 33537 | AUXILIARY LIFT DOWN VALVE - SHORT TO GROUND | blocking fault |
| 33538 | AUXILIARY LIFT DOWN VALVE - OPEN CIRCUIT | blocking fault |
| 33539 | AUXILIARY LIFT DOWN VALVE - SHORT TO BATTERY | blocking fault |
| 33674 | PLATFORM POWER - SHORT TO BATTERY | blocking fault |
| 33675 | PLATFORM POWER - OPEN CIRCUIT | blocking fault |
| 33676 | PLATFORM POWER - SHORT TO GROUND | blocking fault |
| 84109 | ELEVATION SWITCH CONTACTS DISAGREEMENT | warning / function limited |
| 99162 | EEPROM FAILURE POWER MODULE - CHECK ALL SETTINGS | blocking fault |