JLG ES series scissor lifts (1930ES, 2030ES, 2630ES, 2646ES, 3246ES)
JLG error code 225 — FUNCTION PROBLEM - STEER RIGHT PERMANENTLY SELECTED
Message on the display: FUNCTION PROBLEM - STEER RIGHT PERMANENTLY SELECTED
Code 225 occurs in machines: JLG ES series, 1932RS, 6RS, 3248RS, 10RS, 4045R, R4045.
warning / function limited
The steer right switch was closed during power-up in platform mode.
Description from the JLG service manual, in the original wording.
Possible causes
The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.
Checks from the manual
- Check if the steer right switch is obstructed or jammed.
- Check steer right switch and its wiring to the platform board. The steer right switch input (24V) is from platform board terminal J11, and its output (24V when closed) is to platform board terminal J1-16.
- Replace platform board.
What service does
A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.
Source: JLG Service and Maintenance Manual, ES series (Diagnostic Trouble Codes section).
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 225 not go away?
RK Rental services JLG lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.