609 609 105609 609 104

JLG ES series scissor lifts (1930ES, 2030ES, 2630ES, 2646ES, 3246ES)

JLG error code 252 — ELEV ANGLE SENSOR HAS NOT BEEN CALIBRATED

Message on the display: ELEV ANGLE SENSOR HAS NOT BEEN CALIBRATED

Code 252 occurs in machines: JLG ES series, 4045R, R4045.

warning / function limited

The elevation angle sensor has not been calibrated.

Description from the JLG service manual, in the original wording.

Possible causes

The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.

Checks from the manual

  • Calibrate the elevation angle sensor to clear fault. See Section 5.5.

What service does

A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.

Source: JLG Service and Maintenance Manual, ES series (Diagnostic Trouble Codes section).

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 252 not go away?

RK Rental services JLG lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

JLG service · JLG parts · All JLG codes of this system

Neighbouring JLG codes