609 609 105609 609 104

JLG ES series scissor lifts (1930ES, 2030ES, 2630ES, 2646ES, 3246ES)

JLG error code 446 — LOGIC SUPPLY VOLTAGE OUT OF RANGE

Message on the display: LOGIC SUPPLY VOLTAGE OUT OF RANGE

Code 446 occurs in machines: JLG ES series, 1932RS, 6RS, 3248RS, 10RS, 4045R, R4045.

blocking fault

The system module logic supply voltage was measured to be out of normal operating range by the interface PCB (<11V).

Description from the JLG service manual, in the original wording.

Possible causes

The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.

Checks from the manual

  • This may be caused by a loose battery terminal, severely discharged batteries, damaged battery, or an improper wire harness connection.
  • Drive, Steer, and Lift Prevented
  • ZAPI - HEALTH (Status LED) - ON

What service does

A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.

Source: JLG Service and Maintenance Manual, ES series (Diagnostic Trouble Codes section).

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 446 not go away?

RK Rental services JLG lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

JLG service · JLG parts · All JLG codes of this system

Neighbouring JLG codes