JLG error code 8212 — LSS PRESSURE SENSOR - DISAGREEMENT

Message on the display: LSS PRESSURE SENSOR - DISAGREEMENT

Code 8212 occurs in machines: JLG 1932RS, 6RS, 3248RS, 10RS, 4045R, R4045.

blocking fault

Pressure Sensor 1 and Pressure Sensor 2 do not agree. The system shall assume the machine is overloaded until the sensors agree.

Description from the JLG service manual, in the original wording.

Possible causes

The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Using the Analyzer LOAD submenu under DIAGNOSTICS check PRES1 and PRES2 readings. They must agree within 75 PSI. With the safety prop engaged check to ensure that the appropriate voltage is being supplied to both sensors and that the wiring and connections are intact. The voltage between pins A and B should read +5V +/- 0.5V with the machine turned on. If the voltage supplied is correct, replace both transducers.; HEALTH (Status LED) - ON

Source: JLG Service and Maintenance Manual, ES series (Diagnostic Trouble Codes section).

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.