Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2140 — Controller Overtemp Cutback
Message on the display: Controller Overtemp Cutback
Code 0x2140 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
warning / function limited
Flash pattern 2-2 (flash code 0x22).
Description from the Genie service manual, in the original wording.
Effect on the machine: Reduced drive torque. Reduced regen- braking torque. Fault Action: None, unless a fault action is programmed in VCL.
Possible causes
- Controller is operating in an extreme environment.
- Excessive load on vehicle. Improper mounting of controller which is preventing controller cooling.
- Controller is performance- limited at this temperature. See Programmer » System Monitor menu » Controller: Temperature.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: Controller’s Heatsink temperature exceeded 85°C. Clear: Bring heatsink temperature below 85°C.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2140 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 0x2109Critical OS General Fault Program execution within the controller encountered a critical problem and could not recover from this.
- 0x210AOS General 2 Fault Program execution within the controller encountered a serious problem and could not recover from this.
- 0x2110Reset Rejected
- 0x2121Undervoltage Cutback
- 0x2131Overvoltage Cutback
- 0x2531Ext 5V Supply Failure Ext 5V Supply Failure Active _ _ _ _ 0x2531 Fault Type(s):