Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2531 — Ext 5V Supply Failure Ext 5V Supply Failure Active _ _ _ _ 0x2531 Fault Type(s):
Message on the display: Ext 5V Supply Failure Ext 5V Supply Failure Active _ _ _ _ 0x2531 Fault Type(s):
Code 0x2531 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
blocking fault
Flash pattern 2-5 (flash code 0x25). Sub-types: 1 = 5V Supply’s voltage is out- of-range. 2 = 5V Supply’s current is out- of-range.
Description from the Genie service manual, in the original wording.
Effect on the machine: Disables the 5V Supply. Fault Action: None, unless a fault action is programmed in VCL.
Possible causes
- External load impedance on the +5V supply is too low. See the System Monitor » Outputs menu: External 5V Supply, _ _ Ext 5V Current. _ _
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: (1) The 5V Supply is outside 5V±10%. (2) The current is outside limits defined by: Ext 5V Supply Min _ _ _ Ext 5V Supply Max _ _ _ Clear: Reset Controller, or reset using the VCL variable Ext 5V Output Enable. _ _ _
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.