Genie error codes
Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
These are codes of the electric drive motor controllers (hexadecimal notation, e.g. 0x2510), separate from the machine control codes. Below are 107 codes with the original message from the manufacturer's manual and its description. They apply to these machines: Genie S-85 XC FE, S-85 XC E, S-60 DC, Z-60 DC. Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
- 0x2510Controller Overcurrent
- 0x2832Current Sensor Fault
- 0x2223Precharge Failed
- 0x2141Controller Severe Undertemp
- 0x2142Controller Severe Overtemp
- 0x2120Severe B+ Undervoltage
- 0x2122Severe KSI Undervoltage
- 0x2130Severe B+ Overvoltage
- 0x2132Severe KSI Overvoltage
- 0x2133Speed Limit Supervision
- 0x2134Travel Control Supervision
- 0x2109Critical OS General Fault Program execution within the controller encountered a critical problem and could not recover from this.
- 0x210AOS General 2 Fault Program execution within the controller encountered a serious problem and could not recover from this.
- 0x2110Reset Rejected
- 0x2140Controller Overtemp Cutback
- 0x2121Undervoltage Cutback
- 0x2131Overvoltage Cutback
- 0x2531Ext 5V Supply Failure Ext 5V Supply Failure Active _ _ _ _ 0x2531 Fault Type(s):
- 0x2532Ext 12V Supply Failure Fault Type(s):
- 0x2151Motor Temp Hot Cutback
- 0x2150Motor Temp Sensor
- 0x2222Main Driver Fault Type(s):
- 0x2320EM Brake Driver Fault Type(s):
- 0x2232Sin Cos Motor Feedback 1. The signals from the sensor are above the configuration by 10% or at/above the supply rails for >100ms. 2. Sensor failure.
- 0x2230Encoder Fault Fault Type(s):
- 0x2240Motor Open Fault
- 0x2220Main Contactor Welded
- 0x2221Main Contactor Did Not Close Fault Type(s):
- 0x2103Motor Setup Needed Fault Type(s): Hex # Bit1 – 4 Binary 0000 => bits 4 3 2 1
- 0x2102Motor Misalignment Error
Showing the first 30: type more digits of the code.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.