Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2160 — Driver 1 Fault Fault Type(s):
Message on the display: Driver 1 Fault Fault Type(s):
Code 0x2160 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
blocking fault
Flash pattern 10-1 (flash code 0xA1). Sub-types: 1 = Driver Short 2 = Driver Overcurrent 3 = Open/Short (High, should be Low) 4 = Open/Short (Low, should be High) 5 = Driver Open Requires driver checks enabled.
Description from the Genie service manual, in the original wording.
Effect on the machine: ShutdownDriver1
Possible causes
- Open or short on driver load. Dirty connector pins at controller or contactor coil.
- Bad connector crimps or faulty wiring. Driver overcurrent, as set by the Driver 1 Overcurrent parameter. See Programmer » Controller Setup » Outputs » Driver 1 » Driver 1 Overcurrent.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: Driver 1 is either open or shorted, or Driver 1 exceeded its overcurrent setting. Clear: Correct the open or short, and then Reset Controller.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2160 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 0x2833Pump Hardware Error Fault Type(s):
- 0x2812Parameter Mismatch
- 0x2332Interlock Braking Supervision Fault Type(s):1 = Motor speed is outside the Interlock Brake Supervision Speed Limit.
- 0x2161Driver 2 Fault Fault Type(s): See Driver 1 Fault
- 0x2162Driver 3 Fault Fault Type(s): See Driver 1 Fault
- 0x2163Driver 4 Fault Fault Type(s): See Driver 1 Fault