Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2833 — Pump Hardware Error Fault Type(s):
Message on the display: Pump Hardware Error Fault Type(s):
Code 0x2833 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
blocking fault
Flash pattern 9-7 (flash code 0x97). Sub-types: 1 = Duty cycle not update with the update timeframe. 2 = Mismatch of the Commanded pump duty cycle vs. output.
Description from the Genie service manual, in the original wording.
Effect on the machine: Shutdown Pump
Possible causes
- External short of the pump motor.
- Controller defective.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Clear: Reset Controller.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2833 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system