609 609 105609 609 104

Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers

Genie error code 0x2510 — Controller Overcurrent

Message on the display: Controller Overcurrent

Code 0x2510 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.

blocking fault

Flash pattern 1-2 (flash code 0x12). Sub-types: 1 = Controller Over Current Phase U 2 = Controller Over Current Phase W 3 = Controller Over Current Phase V 4 = Irms > 135% Current Limit

Description from the Genie service manual, in the original wording.

Effect on the machine: ShutdownVehicle: ShutdownMotor ShutdownMainContactor ShutdownEMBrakex ShutdownThrottle FullBrake ShutdownPump

Possible causes

  • External short of phase U, V, or W motor connections.
  • Speed encoder noise problems.
  • Motor parameters are mistuned.
  • Controller defective

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Reset Controller

Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 0x2510 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system

Neighbouring Genie codes