Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2223 — Precharge Failed
Message on the display: Precharge Failed
Code 0x2223 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
blocking fault
Flash pattern 1-4 (flash code 0x14). Sub-types: 1 = Abort. 2 = Energy Limit Exceeded. 3 = Time Limit Exceeded.
Description from the Genie service manual, in the original wording.
Effect on the machine: ShutdownVehicle: ShutdownMotor ShutdownMainContactor ShutdownEMBrake ShutdownThrottle FullBrake ShutdownPump
Possible causes
- An external load on the capacitor bank (B+ connection terminal) that prevents the capacitor bank from charging. See Programmer » System Monitor menu » Controller » Capacitor Voltage.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: The precharge failed to charge the capacitor bank. Clear: Cycle Interlock or Reset Controller.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2223 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
