Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2620 — Analog 1/ Pin 16 Out of Range Fault Type(s):
Message on the display: Analog 1/ Pin 16 Out of Range Fault Type(s):
Code 0x2620 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
blocking fault
Flash pattern 11-1 (flash code 0xB1). Sub-types: 1 = above High limit. 2 = below Low limit.
Description from the Genie service manual, in the original wording.
Effect on the machine: Fault Action: None, unless a fault action is programmed in VCL.
Possible causes
- Analog 1 input voltage is above the parameter setting of Analog 1 High.
- Analog 1 input voltage is below the parameter setting of Analog 1 Low. See Programmer » Controller Setup » Analog Inputs » Analog
- See Programmer » Controller Setup » Analog Inputs » Configure » Analog 1 Low / Analog 1 High.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: (1) Input voltage (on pin) is above the parameter’s set-point threshold. (2) Input voltage (on pin) is below the parameter’s set-point threshold. Clear: Return the voltage to within the allowed range, then Reset Controller.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2620 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system