Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2815 — Bad Firmware
Message on the display: Bad Firmware
Code 0x2815 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
blocking fault
Flash pattern 9-1 (flash code 0x91).
Description from the Genie service manual, in the original wording.
Effect on the machine: Controller does not fully startup (without error).
Possible causes
- The firmware in the controller is incorrect.
- The CRC of the application or OS does not match.
- The application was built with an incompatible OS version.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: The loaded software is not compatible with the controller hardware. Clear: Load the matching software. Verify that the controller model matches the cdev version for the project and the VCL Studio application.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2815 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.