609 609 105609 609 104

Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers

Genie error code 0x2321 — EM Brake Failed To Set

Message on the display: EM Brake Failed To Set

Code 0x2321 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.

blocking fault

Flash pattern 9-2 (flash code 0x92).

Description from the Genie service manual, in the original wording.

Effect on the machine: Position Hold is engaged when Interlock = On. Fault Action: None, unless a fault action is programmed in VCL.

Possible causes

  • Vehicle movement sensed after the EM Brake has been commanded to set.
  • EM Brake will not hold the motor from rotating.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Set: After the EM Brake was commanded to set and time has elapsed to allow the brake to fully engage, vehicle movement has been sensed. Clear: 1. Activate the Throttle (EM Brake type 2). 2. Activate the Interlock (EM Brake type 1).

Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 0x2321 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.