Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2820 — VCL Run Time Error
Message on the display: VCL Run Time Error
Code 0x2820 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
blocking fault
Flash pattern 6-8 (flash code 0x68).
Description from the Genie service manual, in the original wording.
Effect on the machine: ShutdownAll: ShutdownMotor ShutdownMainContactor ShutdownEMBrake ShutdownThrottle ShutdownInterlock ShutdownDriver1 to 7 ShutdownPD FullBrake ShutdownPump ShutdownCoilSupply ShutdownVehicle ShutdownLower ShutdownLift
Possible causes
- Runtime errors are defined using the VCL Error Module and VCL Error. See the System Information file: Curtis Software Suite™ » VCL Studio » Help Using driver control commands in VCL can lead to VCL runtime errors if the VCL command and the driver assignment do not match.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: VCL Run Time Error detected. Clear: Edit the VCL application software to fix this error condition; flash the new compiled software and matching parameter settings; Reset Controller.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2820 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system