Genie DC and FE electric boom lifts (Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE, Z-33/18 DC)
Genie error code 140-49 — Pump & Drive Controllers — Parameter Change Fault
Message on the display: Pump & Drive Controllers — Parameter Change Fault
Code 140-49 occurs in machines: Genie Z-45 DC, Z-45 FE.
blocking fault
Controller IDs: 136=Pump [ECON] 137=Left Front [LF] 138=Right Front [RF] 139=Left Rear [LR] 140=Right Rear [RR]
Description from the Genie service manual, in the original wording.
Effect on the machine: ShutdownMotor; ShutdownMainContactor; ShutdownEMBrake; ShutdownThrottle; FullBrake.
Possible causes
- This is a safety fault caused by a change in certain parameter settings so that the vehicle will not operate until KSI is cycled. For example, if a user changes the Throttle Type this fault will appear and require cycling key switch before the vehicle can operate.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: Adjustment of a parameter setting that requires cycling of key switch. Clear: Cycle key switch.
Source: Genie Service and Repair Manuals (Part No. 1307785, 1299608, 1297714, 1271125, 1268514), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 140-49 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 140-38Pump & Drive Controllers — Main Contactor Welded (RRDCON & ECON only)
- 140-39Pump & Drive Controllers — Main Contactor Did Not Close (RRDCON & ECON only)
- 140-46Pump & Drive Controllers — EEPROM Failure
- 140-68Pump & Drive Controllers — VCL Runtime Error
- 140-71Pump & Drive Controllers — OS General
- 140-72Pump & Drive Controllers — PDO Timeout