Genie DC and FE electric boom lifts (Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE, Z-33/18 DC)
Genie error code 140-39 — Pump & Drive Controllers — Main Contactor Did Not Close (RRDCON & ECON only)
Message on the display: Pump & Drive Controllers — Main Contactor Did Not Close (RRDCON & ECON only)
Code 140-39 occurs in machines: Genie Z-45 DC, Z-45 FE.
blocking fault
Controller IDs: 136=Pump [ECON] 137=Left Front [LF] 138=Right Front [RF] 139=Left Rear [LR] 140=Right Rear [RR]
Description from the Genie service manual, in the original wording.
Effect on the machine: ShutdownMotor; ShutdownMainContactor; ShutdownEMBrake; ShutdownThrottle; FullBrake.
Possible causes
- Main contactor did not close.
- Main contactor tips are oxidized, burned, or not making good contact.
- External load on capacitor bank (B+ connection terminal) that prevents capacitor bank from charging.
- Blown B+ fuse.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: Just prior to the main contactor closing, the capacitor bank voltage (B+ connection terminal) was loaded for a short time and the voltage did not discharge. Clear: Cycle key switch.
Source: Genie Service and Repair Manuals (Part No. 1307785, 1299608, 1297714, 1271125, 1268514), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 140-39 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 140-36Pump & Drive Controllers — Encoder Fault
- 140-37Pump & Drive Controllers — Motor Open
- 140-38Pump & Drive Controllers — Main Contactor Welded (RRDCON & ECON only)
- 140-46Pump & Drive Controllers — EEPROM Failure
- 140-49Pump & Drive Controllers — Parameter Change Fault
- 140-68Pump & Drive Controllers — VCL Runtime Error