Genie DC and FE electric boom lifts (Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE, Z-33/18 DC)
Genie error code 204-24 — Main Battery Power Pack Voltage — Value too low
Message on the display: Main Battery Power Pack Voltage — Value too low
Code 204-24 occurs in machines: Genie S-60 DC, Z-33/18 DC.
warning / function limited
The Genie display shows code 204-24 with the message “Main Battery Power Pack Voltage — Value too low”. It is a warning: some functions of the machine may be limited until the cause has been removed.
Possible causes
- Main 48V battery package voltage is below minimum rating
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Recharge the battery package, check for any wiring issue on the 48V power wirings paths
Source: Genie Service and Repair Manuals (Part No. 1307785, 1299608, 1297714, 1271125, 1268514), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 204-24 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 204-19BATTERY _ PWR Battery Power Notes: AUX is available Drive is locked out — OUT OF RANGE
- 204-21Main Battery (Charger) — Fault
- 204-23Main Battery Power Pack Voltage — Value too high
- 205-12Drive Power Contactor — VALUE TOO HIGH
- 205-13Drive Power Contactor — VALUE TOO LOW
- 205-21Drive Power Contactor — Fault