609 609 105609 609 104

Genie DC and FE electric boom lifts (Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE, Z-33/18 DC)

Genie error code 63-16 — Steer Angle Sensor — Value at 0 V

Message on the display: Steer Angle Sensor — Value at 0 V

Code 63-16 occurs in machines: Genie Z-60 DC.

warning / function limited

The Genie display shows code 63-16 with the message “Steer Angle Sensor — Value at 0 V”. It is a warning: some functions of the machine may be limited until the cause has been removed.

Effect on the machine: High speed drive disabled

Possible causes

  • 0V

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Verify: · 12V supply Pin A & RRDCON C28-25 (P198SEN RD) in relation to C28-7 RRDCON (Sensor Ground) · 500-4500mV through steer motion at PIN B &C28-24 (C111LFS OR) and has no open/short circuit to either pin A or pin C · When wheels are straight, signal must be between 2200 & 3400 mV

Source: Genie Service and Repair Manuals (Part No. 1307785, 1299608, 1297714, 1271125, 1268514), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 63-16 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system

Neighbouring Genie codes