609 609 105609 609 104

Genie DC and FE electric boom lifts (Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE, Z-33/18 DC)

Genie error code 89-12 — Fuel Level Sensor — Value too high

Message on the display: Fuel Level Sensor — Value too high

Code 89-12 occurs in machines: Genie S-60 DC, Z-45 DC, Z-45 FE.

message

The Genie display shows code 89-12 with the message “Fuel Level Sensor — Value too high”. It is an information message and does not need any reaction.

Effect on the machine: Display fault code only

Possible causes

  • Signal > 4900 mV

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Verify: · 24V supply on pin A of sensor · B1 on pin C · 1700 - 4500 mV on pin B

Source: Genie Service and Repair Manuals (Part No. 1307785, 1299608, 1297714, 1271125, 1268514), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 89-12 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system

Neighbouring Genie codes