609 609 105609 609 104

Genie DC and FE electric boom lifts (Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE, Z-33/18 DC)

Genie error code 95-24 — Engine Rpm — Value too low

Message on the display: Engine Rpm — Value too low

Code 95-24 occurs in machines: Genie Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE.

warning / function limited

The Genie display shows code 95-24 with the message “Engine Rpm — Value too low”. It is a warning: some functions of the machine may be limited until the cause has been removed.

Effect on the machine: Hybrid Mode disabled

Possible causes

  • Engine Speed lower than setting

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Verify: · Over temperature switch is not activating Relay CR64 by providing a ground path to the relay coil {unplug oil pressure switch for this test} (C108SEL WH/BK) · Oil Pressure Switch contacts open to B- after engine start (C108SEL WH/BK) · Relay CR64 is operable. Output of relay CR64- 87 is connected to C27-4 LRDCON through C35-1 (R108SEL WH/BK)

Source: Genie Service and Repair Manuals (Part No. 1307785, 1299608, 1297714, 1271125, 1268514), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 95-24 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.