Genie with Ford engine (petrol/LPG): ECM engine controller codes

Genie error code 121 — Closed Loop Multiplier High (Gasoline)

Message on the display: Closed Loop Multiplier High (Gasoline)

Code 121 occurs in machines: Genie Z-80/60, S-80, S-85, GS-3384 RT, GS-3390, GS-4390, GS-5390, Z-60/34, S-40, S-45.

warning / function limited

The Genie display shows code 121 with the message “Closed Loop Multiplier High (Gasoline)”. It is a warning: some functions of the machine may be limited until the cause has been removed.

Possible causes

  • Heated Oxygen Sensor wiring and/or connections open or shorted.
  • sensor is faulty.
  • there are vacuum leaks or exhaust leaks.
  • fuel pressure is low.
  • the fuel injectors need cleaning or replacing.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Repair wiring and/or connections OR replace sensor OR repair any vacuum and exhaust leaks OR test the fuel pressure OR clean or replace the fuel injectors.

Source: Genie Service Manuals S-60/S-65 (65196), S-80/S-85 (111165), Z-80/60 (88619), GS-3384 (82259), GS-3390/4390/5390 (72863), Ford Engine ECM Fault Code Chart.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 121 not go away?