Genie S-40 XC
Genie error code 44-27 — Drive Enable Toggle Switch — Active at startup
Message on the display: Drive Enable Toggle Switch — Active at startup
Code 44-27 occurs in machines: Genie S-40 XC.
warning / function limited
The Genie display shows code 44-27 with the message “Drive Enable Toggle Switch — Active at startup”. It is a warning: some functions of the machine may be limited until the cause has been removed.
Effect on the machine: Drive Enable switch will not operate, possibly preventing drive while the turntable is rotated.
Possible causes
- Toggle switch input was detected as HIGH at start-up.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
* Verify with a voltmeter that the Drive Enable Toggle Switch (TS15) is operating properly. * C143DEL (BL/RD, PCON J16-7) should be 0 V with the switch OFF and 12 V with the switch held in the ON position. * Cycle power to allow the machine to re- test the fault.
Source: Genie Service and Repair Manual S-40 XC (Part No. 1322629, 1286829GT), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 44-27 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 42-11Turntable Rotate CW Coil — Shorted to supply voltage
- 43-9Turntable Rotate CCW Coil — Shorted to GND
- 43-11Turntable Rotate CCW Coil — Shorted to supply voltage
- 45-27Platform Level Toggle Switch — Active at startup
- 46-9Platform Rotate CW Coil — Shorted to GND
- 46-11Platform Rotate CW Coil — Shorted to supply voltage