Genie S-40 XC
Genie error code 79-13 — Display Controller (DISCON) — Not detected
Message on the display: Display Controller (DISCON) — Not detected
Code 79-13 occurs in machines: Genie S-40 XC.
blocking fault
The Genie display shows code 79-13 with the message “Display Controller (DISCON) — Not detected”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.
Effect on the machine: Controls from the ground will not operate.
Possible causes
- TCON has not detected the DISCON on the communications bus.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
* Verify DISCON is operating by checking that the display on the front is operating properly. * If there is no display, try to power up the DISCON by setting the key switch to Ground, pull out the ground ESTOP and press the Ground Function Enable button. The display should start. * If there is still no display, check DISCON power on J10 pins 2 (+) and 1 (-). * If DISCON operates but fault persists, check the CAN bus wiring. Disconnect J10 and with a voltmeter set to resistance verify that the resistance between pins 3 and 4 on the harness connector are between 55 and 65 ohms. Check CAN wiring if resistance check fails. * Replace DISCON if required.
Source: Genie Service and Repair Manual S-40 XC (Part No. 1322629, 1286829GT), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 79-13 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 78-13Platform Controller (PCON) — Not detected
- 78-29Platform Controller (PCON) — Software version mismatch
- 78-36Platform Controller (PCON) — Not detected
- 79-29Display Controller (DISCON) — Software version mismatch
- 80-13Turntable Controller (TCON) — Not detected
- 80-29Turntable Controller (TCON) — Software version mismatch