Genie error code 84-21 — Chassis Angle — Turntable Tilt Sensor Internal Error.

Message on the display: Chassis Angle — Turntable Tilt Sensor Internal Error.

Code 84-21 occurs in machines: Genie S-40 XC.

blocking fault

The Genie display shows code 84-21 with the message “Chassis Angle — Turntable Tilt Sensor Internal Error”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Boom Up, Extend, Turntable Rotate and Drive functions will not operate until stowed. Boom Up and Extend inhibited while stowed.

Possible causes

  • An internal error flag has been exhibited in the tilt sensors.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

* Cycle power to allow the machine to re- test the fault. * Replace tilt sensor.

Source: Genie Service and Repair Manual S-40 XC (Part No. 1322629, 1286829GT), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.