Genie S-40 XC
Genie error code 89-12 — Fuel Level Sensor — Sensor value too high
Message on the display: Fuel Level Sensor — Sensor value too high
Code 89-12 occurs in machines: Genie S-40 XC.
message
The Genie display shows code 89-12 with the message “Fuel Level Sensor — Sensor value too high”. It is an information message and does not need any reaction.
Effect on the machine: None. Informational only.
Possible causes
- Fuel level sensor shorted to 12 V.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
* Verify sensor power. * Replace sensor if necessary.
Source: Genie Service and Repair Manual S-40 XC (Part No. 1322629, 1286829GT), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 89-12 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 84-21Chassis Angle — Turntable Tilt Sensor Internal Error.
- 88-9Function Enable Coil — Shorted to GND
- 88-11Function Enable Coil — Shorted to supply voltage
- 89-15Fuel Level Sensor — Sensor value too low
- 92-9Turntable Rotate Flow Coil — Shorted to GND
- 92-11Turntable Rotate Flow Coil — Shorted to supply voltage