609 609 105609 609 104

Genie S-85 XC FE and S-85 XC E (hybrid and electric drive)

Genie error code 17-25 — Auxiliary contactor fault — Resistance too high

Message on the display: Auxiliary contactor fault — Resistance too high

Code 17-25 occurs in machines: Genie S-85 XC FE, S-85 XC E.

blocking fault

The Genie display shows code 17-25 with the message “Auxiliary contactor fault — Resistance too high”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Auxiliary pump controller function disabled Auxiliary battery charging function disabled

Possible causes

  • Contactor not suppling power

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

* AUX battery fuse is good. * AUX relay output fuse is good. * AUX relay is functioning. * 24V at TCON pin J2-19 with toggle switch activated (V27AUX RD/WH). * 24V across relay terminals 85 and 86 with toggle switch activated.

Source: Genie Service and Repair Manual S-85 XC FE / E (Part No. 1337498), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 17-25 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system