609 609 105609 609 104

Genie XC, HF and J boom lifts (S-60 XC, S-80 XC, S-85 XC, S-80 HF, S-85 HF, S-60 J, S-80 J)

Genie error code 71-16 — TCON — Fault

Message on the display: TCON — Fault

Code 71-16 occurs in machines: Genie S-60 XC, S-80 XC, S-85 XC, S-80 HF, S-85 HF.

blocking fault

The Genie display shows code 71-16 with the message “TCON — Fault”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Unable to enter any ground or platform modes, as Estop is considered OFF in this state.

Possible causes

  • Output to the Estop Circuit is shorted to Ground (B-).

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

* Cycle power to allow the machine to re- test the fault.

Source: Genie Service and Repair Manuals (Part No. 1316494, 1315679, 1288652, 1280490, 1285305, 1285307), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 71-16 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system

Neighbouring Genie codes