Genie XC, HF and J boom lifts (S-60 XC, S-80 XC, S-85 XC, S-80 HF, S-85 HF, S-60 J, S-80 J)

Genie error code 71-22 — ESTOP Circuit — ESTOP Source circuit is shorted to GND

Message on the display: ESTOP Circuit — ESTOP Source circuit is shorted to GND

Code 71-22 occurs in machines: Genie S-60 XC, S-80 XC, S-85 XC, S-80 HF, S-85 HF.

blocking fault

The Genie display shows code 71-22 with the message “ESTOP Circuit — ESTOP Source circuit is shorted to GND”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: ESTOP circuit cannot complete, preventing machine functions.

Possible causes

  • TCON detected that ESTOP 1 is at 12 V but ESTOP 3 is at 0 V.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

* Using a voltmeter and with the system turned OFF, check the resistance between TCON J5 pins 9 and 10. Replace TCON if resistance is more than 5 ohms.

Source: Genie Service and Repair Manuals (Part No. 1316494, 1315679, 1288652, 1280490, 1285305, 1285307), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.