Haulotte error code F05.06 — Signal out of range or inconsistent neutral value on rotation /lift joystick
Message on the display: Signal out of range or inconsistent neutral value on rotation /lift joystick
Code F05.06 occurs in machines: Haulotte HA12CJ, HA32CJ, HA12CJ+, HA32CJ+.
blocking fault
Signal out of range or inconsistent neutral value on rotation /lift joystick
Description from the Haulotte service manual, in the original wording.
Possible causes
- Check connection and signal value (0.5 - 2.5 - 4.5VDC)
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
What service does
A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.
Source: Haulotte Maintenance Book HA12 CJ (4000786480), fault code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code F05.06 not go away?
RK Rental services Haulotte lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Haulotte service · Haulotte parts · All Haulotte codes of this system
Neighbouring Haulotte codes
- F04.12Output in open or short circuit : PWM valve for secondary movements YV0 is defective (or missing) or wire is cut
- F05.01Signal out of range or inconsistent neutral value on drive joystick
- F05.04Signal out of range or inconsistent neutral value on rotation /lift joystick
- F06.01Adress fault on slave module doing the load function Inconsistant values between EEPROM datas saved between module master B2 and slave B3 / Fault in Jib learning Cal 1
- F06.02Inconsistent values for the calculation of the pressure recorded between modules node B2 master and slave B3 / Inconsistent values for the calculation of the pressure reference between modules node B2 master and node B3 slave
- F07.01Incoherent status of sensors : No change during movement