Haulotte HA12 CJ and HA12 CJ+ (HA32 CJ)
Haulotte error code F07.01 — Incoherent status of sensors : No change during movement
Message on the display: Incoherent status of sensors : No change during movement
Code F07.01 occurs in machines: Haulotte HA12CJ, HA32CJ, HA12CJ+, HA32CJ+.
blocking fault
Incoherent status of sensors : No change during movement
Description from the Haulotte service manual, in the original wording.
Possible causes
- Check wiring and sensors SQ9 and SQ34 :
- Telescopic IN SQ9=1
- Boom + arm stowed, SQ34=1
- Move both movements (telescopic then arm + boom) and check if failure has disappeared
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Check wiring and sensors SQ9 and SQ34 : • Telescopic IN SQ9=1 • Boom + arm stowed, SQ34=1 • Move both movements (telescopic then arm + boom) and check if failure has disappeared
Source: Haulotte Maintenance Book HA12 CJ (4000786480), fault code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code F07.01 not go away?
RK Rental services Haulotte lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Haulotte service · Haulotte parts · All Haulotte codes of this system
Neighbouring Haulotte codes
- F05.06Signal out of range or inconsistent neutral value on rotation /lift joystick
- F06.01Adress fault on slave module doing the load function Inconsistant values between EEPROM datas saved between module master B2 and slave B3 / Fault in Jib learning Cal 1
- F06.02Inconsistent values for the calculation of the pressure recorded between modules node B2 master and slave B3 / Inconsistent values for the calculation of the pressure reference between modules node B2 master and node B3 slave
- F07.20Fault in G1 pressure sensor in jib cylinder Pressure variation too important in the jib small chamber
- F07.21Fault in G2 pressure sensor in jib cylinder Pressure variation too important in the jib large chamber
- F07.22Inconsistent values between jib movement and jib angle measurement Fault in A1 relative angle sensor