609 609 105609 609 104

Haulotte HA12 CJ and HA12 CJ+ (HA32 CJ)

Haulotte error code F06.02 — Inconsistent values for the calculation of the pressure recorded between modules node B2 master and slave B3 / Inconsistent values for the calculation of the pressure reference between modules node B2 master and node B3 slave

Message on the display: Inconsistent values for the calculation of the pressure recorded between modules node B2 master and slave B3 / Inconsistent values for the calculation of the pressure reference between modules node B2 master and node B3 slave

Code F06.02 occurs in machines: Haulotte HA12CJ, HA32CJ, HA12CJ+, HA32CJ+.

blocking fault

Inconsistent values for the calculation of the pressure recorded between modules node B2 master and slave B3 Inconsistent values for the calculation of the pressure reference between modules node B2 master and node B3 slave

Description from the Haulotte service manual, in the original wording.

Possible causes

  • Too much difference of calculation regarding the pressure datas between modules node B2 and B3
  • Restart the machine
  • Change module node B2 and/or node B3
  • Difference more than 2 seconds between the reference pressure(Calibration value)
  • Registered by module node B3 and the current one registered by the master module node B2

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Too much difference of calculation regarding the pressure datas between modules node B2 and B3 • Restart the machine • Change module node B2 and/or node B3 Difference more than 2 seconds between the reference pressure(Calibration value) • Registered by module node B3 and the current one registered by the master module node B2

Source: Haulotte Maintenance Book HA12 CJ (4000786480), fault code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code F06.02 not go away?

RK Rental services Haulotte lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Haulotte service · Haulotte parts · All Haulotte codes of this system