Zoomlion error codes
Zoomlion ZS series scissor lifts (ZS0407, ZS0607, ZS0608, ZS0808, ZS0812, ZS1012, ZS1212, ZS1414)
The two-character code (e.g. 01, 52, LL) is shown on the LED diagnostic display of the platform control box and on the LCD of the ground control box. The fault must be removed before work resumes. Below are 101 codes with the fault name from the manufacturer's manual and its description. They apply to these machines: Zoomlion ZS0407, ZS0607, ZS0608, ZS0808, ZS0812, ZS1012, ZS1212, ZS1414 (DC, DC-Li, AC, AC-Li versions) and ZS0508C, ZS0610C, ZS0612C, ZS1216C. Source: Zoomlion Service and Maintenance Manual for scissor lifts, Polish edition (version C, March 2023), tables 3-1 and 3-2. The manufacturer's manual for these machines is available only in Polish. The fault names and descriptions marked as translated are our English translation of the Polish edition, not the manufacturer's own wording. That applies to 75 of the 101 codes; the others are given in English in the manual itself and are quoted unchanged.
- 01System Initialisation Fault
- 02System Communication Fault
- 03Invalid Option Setting Fault
- 04Calibration Fault
- 09GPS Communication Fault
- 10CAN Communication Fault
- 12Chassis Up or Down Switch ON
- 14CAN Communication Fault (Pump Motor Controller)
- 15CAN Communication Fault (Drive Motor Controller)
- 18Pothole Guard Fault
- 20BMS Communication Fault
- 21Discharge Temperature Fault I
- 22Discharge Current High Fault I
- 23Total Voltage Low Fault I
- 24Cell Voltage Low Fault I
- 25Cell Voltage Low Fault II
- 26Sharp Difference in Voltage
- 27Sharp Difference in Temperature
- 28Discharge Current High Fault II
- 29Discharge Temperature Fault II
- 31Pressure Sensor Fault
- 32Angle Sensor Fault
- 35Pressure Sensor 2 Fault
- 36Battery Drain Alarm
- 37Battery Discharged
- 38SPI Communication Fault
- 42Platform Left Button ON
- 43Platform Right Button ON
- 46Platform Enable Button ON
- 47Joystick Not in Neutral
Showing the first 30: type more digits of the code.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.