Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x211A — Motor Bracking Impaired
Message on the display: Motor Bracking Impaired
Code 0x211A occurs in machines: Genie S-85 XC FE, S-85 XC E.
blocking fault
Flash pattern 8-4 (flash code 0x84).
Description from the Genie service manual, in the original wording.
Effect on the machine: ShutdownInterlock
Possible causes
- Battery Overcharged
- Excessive motor or controller heating
- Misadjusted parameters
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: OverallCutback (0x32D9) fell below Motor Braking _ _ Impaired Threshold for _ Motor _ Braking Impaired Time _ _ during regen (braking). Clear: Reset interlock.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x211A not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 0x2111Autobaud Failure on linked controller CAN port
- 0x2113Primary State Error
- 0x2870Hardware Compatibility
- 0x211CHazardous Movement 1
- 0x212AMemory Parity An internal memory error occurred. Fault Type: Indicates in which memory or peripheral the fault occurred.
- 0x2250Dual Severe A severe failure has on either of the controllers setup for dual drive.