Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x212A — Memory Parity An internal memory error occurred. Fault Type: Indicates in which memory or peripheral the fault occurred.
Message on the display: Memory Parity An internal memory error occurred. Fault Type: Indicates in which memory or peripheral the fault occurred.
Code 0x212A occurs in machines: Genie S-85 XC FE, S-85 XC E.
blocking fault
Flash pattern 15-1 (flash code 0xF1).
Description from the Genie service manual, in the original wording.
Effect on the machine: ShutdownVehicle
Possible causes
- An electromagnetic transient may have caused a bit to change state. Possible damage to the microcontroller may have caused a memory cell to not operate properly.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Reset Controlle.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x212A not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 0x2870Hardware Compatibility
- 0x211AMotor Bracking Impaired
- 0x211CHazardous Movement 1
- 0x2250Dual Severe A severe failure has on either of the controllers setup for dual drive.
- 0x2253Dual PDO Timeout The time between DD CAN PDO messages received exceeded the PDO Timeout period (52ms). Fault Type(s): 1
- 0x2330EMER Rev Timeout Emergency Reverse was activated and ran until the EMR Timeout timer expired. Fault Type(s): 1