609 609 105609 609 104

Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers

Genie error code 0x2230 — Encoder Fault Fault Type(s):

Message on the display: Encoder Fault Fault Type(s):

Code 0x2230 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.

blocking fault

Flash pattern 3-6 (flash code 0x36). Sub-types: 1 = Loss of regulation. 2 = Over Current trips Loss of pulses. 3 = Loss of speed signal pulses. 4 = Autocharacterization 5 = Encoder supply (voltage) fault.

Description from the Genie service manual, in the original wording.

Effect on the machine: ShutdownEMBrake ShutdownThrottle ShutdownMotor

Possible causes

  • Motor encoder failure.
  • Bad crimps or faulty wiring. See Programmer » System Monitor menu » AC Motor: Motor RPM. See Programmer » AC Motor Setup » Quadrature Encoder » Encoder fault Setup.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Set: Motor encoder phase failure detected. Clear: Either Reset Controller, or if parameter LOS Upon Encoder Fault = On and Interlock has been cycled, then the Encoder Fault is cleared and Encoder LOS fault (flash code 9-3) is set, allowing limited motor control.

Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.