Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2450 — Pump Battery Discharge Indicator (BDI)
Message on the display: Pump Battery Discharge Indicator (BDI)
Code 0x2450 occurs in machines: Genie S-85 XC FE, S-85 XC E, Z-60 DC, S-60 DC.
warning / function limited
Flash pattern 9-6 (flash code 0x96).
Description from the Genie service manual, in the original wording.
Effect on the machine: ShutdownPump
Possible causes
- The BDI is below the Lift BDI Lockout setting. _ _
- BDI parameters are mistuned.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: Pump activated when the BDI Percentage is below the Lift Battery lockout setting. Clear: Charge battery.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2450 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
