Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2330 — EMER Rev Timeout Emergency Reverse was activated and ran until the EMR Timeout timer expired. Fault Type(s): 1
Message on the display: EMER Rev Timeout Emergency Reverse was activated and ran until the EMR Timeout timer expired. Fault Type(s): 1
Code 0x2330 occurs in machines: Genie S-85 XC FE, S-85 XC E.
blocking fault
Flash pattern 9-4 (flash code 0x94).
Description from the Genie service manual, in the original wording.
Effect on the machine: Shutdown Throttle Shutdown Embrake
Possible causes
- Emergency Reverse was activated and concluded because the EMR Timeout timer has expired. The emergency reverse input is stuck On
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Turn the emergency reverse input (switch) to Off.
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2330 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 0x212AMemory Parity An internal memory error occurred. Fault Type: Indicates in which memory or peripheral the fault occurred.
- 0x2250Dual Severe A severe failure has on either of the controllers setup for dual drive.
- 0x2253Dual PDO Timeout The time between DD CAN PDO messages received exceeded the PDO Timeout period (52ms). Fault Type(s): 1
- 0x2331EMER REV HPD At the conclusion of Emergency Reverse, the fault was set because various inputs were not returned to neutral. Fault Type(s): 1
- 0x2333EMER Supervision During an EMR event, the motor speed exceeded the limit set by the Emergency Reverse Supervision parameters. Fault Type(s): 1
- 0x2871ECC Run Time Error An embedded C application has encountered a runtime error. Fault Type(s)