609 609 105609 609 104

Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers

Genie error code 0x2330 — EMER Rev Timeout Emergency Reverse was activated and ran until the EMR Timeout timer expired. Fault Type(s): 1

Message on the display: EMER Rev Timeout Emergency Reverse was activated and ran until the EMR Timeout timer expired. Fault Type(s): 1

Code 0x2330 occurs in machines: Genie S-85 XC FE, S-85 XC E.

blocking fault

Flash pattern 9-4 (flash code 0x94).

Description from the Genie service manual, in the original wording.

Effect on the machine: Shutdown Throttle Shutdown Embrake

Possible causes

  • Emergency Reverse was activated and concluded because the EMR Timeout timer has expired. The emergency reverse input is stuck On

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Turn the emergency reverse input (switch) to Off.

Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 0x2330 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system