Genie S-85 XC FE/E, S-60 DC, Z-60 DC: drive motor controllers
Genie error code 0x2871 — ECC Run Time Error An embedded C application has encountered a runtime error. Fault Type(s)
Message on the display: ECC Run Time Error An embedded C application has encountered a runtime error. Fault Type(s)
Code 0x2871 occurs in machines: Genie S-85 XC FE, S-85 XC E.
blocking fault
Flash pattern 6-8 (flash code 0x68). Sub-types: 0 = Hard Fault 1 = Memory Violation 2 = Bus Fault 3 = Usage Fault 4 = Stack Fault 5 = CPU Usage Fault 100 = Heap Fault 101 = Unhandled Exception 10000 (and above) ccapi exception exit All other codes are app-specific application exit code
Description from the Genie service manual, in the original wording.
Effect on the machine: ShutdownAll
Possible causes
- Programming Error
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Edit the ECC application software to fix this error condition; flash the new compiled software and matching parameter settings; Reset Controller
Source: Genie Service and Repair Manuals (Part No. 1337498, 1307785, 1299608), drive controller code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 0x2871 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 0x2330EMER Rev Timeout Emergency Reverse was activated and ran until the EMR Timeout timer expired. Fault Type(s): 1
- 0x2331EMER REV HPD At the conclusion of Emergency Reverse, the fault was set because various inputs were not returned to neutral. Fault Type(s): 1
- 0x2333EMER Supervision During an EMR event, the motor speed exceeded the limit set by the Emergency Reverse Supervision parameters. Fault Type(s): 1
- 0x2890ERU Configuration Bad configuration for EXISEL in the ERU.
- 0x2891Desat Trip DESAT trip detected. Fault flags(s): 0x01 = U phase. 0x02 = U phase. 0x04 = V phase. 0x08 = V phase. 0x10 = W phase. 0x20 = W phase.
- 0x2420PUMP DRIVER FAULT